Set Scheduled Outage
The Set Scheduled Outage object
causes HP OpenView to ignore a collection of messages that match
rules that you specify. Any messages that you disable using the Set
Scheduled Outage object can also be re-enabled using the Set
Scheduled Outage object using the Opalis generated ID of the rule
that was created.
Note: When setting a scheduled outage
it is important to save the outage Id somewhere where it can be
retrieved so that the outage can be disabled later.
How it is used
You can use the Set Scheduled Outage
object to ignore a collection of messages at the start of
maintenance procedure to prevent false messages from being
generated that are related to the maintenance procedure that you
are performing.
Configuration
To configure the Set Scheduled
Outage object you will need to know the rules that define the
messages that you are ignoring or the ID of the message that you
are re-enabling.
Details tab
Add scheduled outage
|
Select to add a scheduled
outage. You will need to specify rules that will be used to define
the messages that will be ignored by the OpenView Operations
server.
|
Remove scheduled outage
|
Select to remove a scheduled
outage that you have created using the Set Scheduled Outage
object.
|
Outage Id
|
Type the Id of the outage that
you created previously using a Set Scheduled Outage object. It is
recommended to use Execution Data from a previous object to set the
Id.
|
Rules
|
The list shows all the rules
for the outage that you have configured. To edit or remove a rule,
select the item and click Edit or Remove respectively. To add a filter,
see the instructions below.
|
To add a rule:
1.
|
Click Add. The Rule dialog appears.
|
2.
|
From the Field drop-down list, select the field
that you want to generate a rule for.
|
3.
|
From the Relation drop-down list, select the
relation that will be used to compare the value of the field to the
Value that you will specify.
|
4.
|
In the Value field, type or select the value
that will be compared to the value of the field that you specified
and click OK. The rule is
added to the list.
|
Note: When specifying a rule that uses
the Node field, you must
specify the node using the IP address.
Available Published Data
Name
|
Description
|
Outage Id
|
The Id of the outage that was
added or removed.
|