Monitoring physical component health
When a warning or critical error occurs in a physical component, the health state of the affected component changes and generates an alert. You can use the alert description and product knowledge to troubleshoot the issue.
If a physical component fails and disappears from the data collected by ESI Service, an alert is generated to investigate the failure. You can use this alert to determine root cause of a failure. You can also use the physical component count values that are stored in the database to detect long term trends.
The following rules are available for each component:
Two collection rules save the count values to the database (DB) and data warehouse (DW) for the specified physical components of a specified class per parent instance.
One warning alert is generated and updated in the active alerts folder in SCOM if a physical-component count changes. If the alert rule for the specified physical component is enabled, the rule collects data every 90 minutes and calculates the total component count. Multiple alert generations are suppressed to reduce the number of alerts generated for the same failure.
Table 1 lists the collection and alert rules that are enabled by default and Table 2 lists the rules that are disabled by default. The total counts for enclosures and LUN storage service nodes includes all of the components in the class hierarchy. The disabled rules are optional for investigating problem alerts. You can enable one or more of the disabled rules when a physical component or hardware problem requires investigation.
Table 1. Enabled component collection and alert rules
Physical component |
Enabled collection and alert rules |
Enclosure |
EMC SI Enclosure Physical Components Total Count Collection Rule (DB) EMC SI Enclosure Physical Components Total Count Collection Rule (DW) EMC SI Enclosure Physical Components Total Count Alert Rule |
LUN storage service node |
EMC SI LUN Storage Service Node Physical Components Total Count Collection Rule (DB) EMC SI LUN Storage Service Node Physical Components Total Count Collection Rule (DW) EMC SI LUN Storage Service Node Physical Components Total Count Alert Rule |
Table 2. Disabled component collection and alert rules
Physical component |
Disabled collection and alert rules |
Cooling component |
EMC SI Cooling Component Count Collection (DB) EMC SI Cooling Component Count Collection (DW) EMC SI Cooling Component Count Alert Rule |
CPU module |
EMC SI CPU Module Count Collection (DB) EMC SI CPU Module Count Collection (DW) EMC SI CPU Module Count Alert Rule |
Device |
EMC SI Storage Device Count Collection (DB) EMC SI Storage Device Count Collection (DW) EMC SI Storage Device Count Alert Rule |
Disk drive |
EMC SI Disk Drive Count Collection(DB) EMC SI Disk Drive Count Collection(DW) EMC SI Disk Drive Count Alert Rule |
Engine (VPLEX) |
EMC SI Engine Count Collection (DB) EMC SI Engine Count Collection (DW) EMC SI Engine Count Alert Rule |
Extent (VPLEX) |
EMC SI Extent Count Collection (DB) EMC SI Extent Count Collection (DW) EMC SI Extent Count Alert Rule |
FC storage port |
EMC SI Fc Storage Port Count Collection (DB) EMC SI Fc Storage Port Count Collection (DW) EMC SI Fc Storage Port Count Alert Rule |
I/O module |
EMC SI IO Module Count Collection (DB) EMC SI IO Module Count Collection (DW) EMC SI IO Module Count Alert Rule |
iSCSI storage port |
EMC SI ISCSI Storage Port Count Collection (DB) EMC SI ISCSI Storage Port Count Collection (DW) EMC SI ISCSI Storage Port Count Alert Rule |
Link control card |
EMC SI Link Control Card Collection (DB) EMC SI Link Control Card Collection (DW) EMC SI Link Control Card Count Alert Rule |
Storage array (VPLEX back-end storage system) |
EMC SI Storage Array Collection (DB) EMC SI Storage Array Collection (DW) EMC SI Storage Array Alert Rule |
Storage service node |
EMC SI Storage Service Node Count Collection (DB) EMC SI Storage Service Node Count Collection (DW) EMC SI Storage Service Node Count Alert Rule |
Storage volume |
EMC SI Storage Volume Count Collection (DB) EMC SI Storage Volume Count Collection (DW) EMC SI Storage Volume Count Alert Rule |
Memory module |
EMC SI Memory Module Count Collection (DB) EMC SI Memory Module Count Collection (DW) EMC SI Memory Module Count Alert Rule |
Network switch |
EMC SI Network Switch Count Collection(DB) EMC SI Network Switch Count Collection(DW) EMC SI Network Switch Count Alert Rule |
Power supply |
EMC SI Power Supply Count Collection (DB) EMC SI Power Supply Count Collection (DW) EMC SI Power Supply Count Alert Rule |
Unclassified port |
EMC SI Unclassified Port Count Collection (DB) EMC SI Unclassified Port Count Collection (DW) EMC SI Unclassified Port Count Alert Rule |
Virtual volume (VPLEX) |
EMC SI Virtual Volume Count Collection (DB) EMC SI Virtual Volume Count Collection (DW) EMC SI Virtual Volume Count Alert Rule |
VplexCluster |
EMC SI VPLEXCluster Count Collection (DB) EMC SI VPLEXCluster Collection (DW) EMC SI VPLEXCluster Alert Rule |