Setting up a nonadministrator account to use the Monitor Manager

The following settings are needed.

Settings

Both the Monitor Manager and the Monitor Service on single system (Default)

Only the Monitor Service on the system

Only the Monitor Manager on the system

Setting A

Required

Not required

Required

Setting B

Required

Required

Read-only registry setting required.

  1. For Setting A, to add file access to the BladeSystem Enclosure Monitor Manager:
    1. Open the File Explorer on the system.
    2. Locate the file folder:
      %ProgramFiles%\HP BladeSystem Management Pack for Operations Manager 2007\Tools
    3. Right-click the file folder, and then in the context menu, select Properties.
    4. Select the Security tab.
    5. To allow read/execute access to the Monitor Manager tool, click Edit and then choose either of the following:
      1. Add Users group ("<Computer Domain Name>\Users").
      2. For non-English operating system, use the appropriate name instead of Users.
    6. Close the dialog, and then exit the File Explorer.
  2. For Setting B, to add file access to the BladeSystem Enclosure Monitor Service and to the BladeSystem Enclosure Monitor Manager:
    1. Open the Registry Editor (regedit.exe) on the system.
    2. Locate the key at HKEY_LOCAL_MACHINE\SOFTWARE\Hewlett-Packard\HP BladeSystem Enclosure Monitor Service.
    3. Right-click the key, and in the context menu, select Permission.
    4. Click Add, and then register a user or a group.
    5. Update the permission to the user or the group:
      • To enable the user or group members managing OA credential data such as add, remove, and update, select the Full Control checkbox.
      • To enable the user to see currently registered OA and status, select the Read checkbox.
    6. Close the permission dialog, and then exit the Registry Editor.

When using with read-only setting, no explicit error message appears stating the nonadministrator account does not have write access to the Monitor Service. The following error message appears when attempting to modify the configuration with read-only access permission.

HP BladeSystem Enclosure Monitor Manager