This topic provides a procedure for creating a self-tuning monitor to measure CPU processor time. The concepts presented here are applicable to other types of self-tuning monitors. After the self-tuning monitor has been created, you will need to wait for one business cycle to complete before alerts will be generated.
Примечание |
---|
Ensure that the length of the business cycle in step 15 is always greater than the length of the interval set in step 14. |
To create a self-tuning monitor
-
In the Essentials 2007 console, click the Authoring button.
-
In the Authoring pane, expand Authoring, expand Management Pack Objects, and then click Monitors.
-
Click the Scope button.
-
In the Scope MP Objects by target(s) dialog box, in the Look for text box, type Windows Computer, select the Windows Computer target check box, and then click OK.
-
In the Monitors pane, in the Look for box, type Windows Computer, select the Windows Computer target check box, and then click OK.
-
In the Monitors pane, expand Windows Computer, expand Entity Health, right-click Performance, point to Create a monitor, and then click Unit Monitor.
Примечание You can either select a Management Pack from the Select destination management pack list or create a new unsealed Management Pack by clicking New. -
In the Create Monitor Wizard, expand Windows Performance Counters, expand Self Tuning Thresholds, click 2-state Baselining, and then click Next.
-
On the General Properties page, in the Name box, type a name for the self-tuning monitor, and then as an option, you can type a description.
-
In the Parent monitor list, click the appropriate parent monitor, and then click Next.
-
On the Performance Object, Counter and Instance page, click Browse.
-
In the Select Performance Counter dialog box, click the down arrow in the Object list, and then click Processor.
-
In Select counter from list, click %Processor Time, and then click OK.
-
On the Performance Object, Counter and Instance page, leave Interval set at the default value of 15 minutes, and then click Next.
-
On the Configure the baseline values used to determine the thresholds page, enter a Business cycle appropriate for your business environment, and then click Next.
Примечание A business cycle is typically one week, or in some cases, one day. -
On the Configure Health page, for each Monitor Condition, click the health state status, click a health state from the drop down list, and then click Next.
-
On the Configure Alerts page, specify the alert settings appropriate for your environment, and then click Create.