The SMS_TaskSequence_RebootAction Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents a task sequence action that specifies restart options for the target computer.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Class SMS_TaskSequence_RebootAction : SMS_TaskSequence_Action
{
	SMS_TaskSequence_Condition Condition;
	Boolean ContinueOnError;
	String Description;
	Boolean Enabled;
	String Message;
	UInt32 MessageTimeout;
	String Name;
	String SupportedEnvironment;
	String Target;
	UInt32 Timeout;
};

Methods

The SMS_TaskSequence_RebootAction class does not define any methods.

Properties

Condition

Data type: SMS_TaskSequence_ConditionAccess type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.
ContinueOnError

Data type: BooleanAccess type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.
Description

Data type: StringAccess type: Read/WriteQualifiers: [AllowedLen("0-255")]See SMS_TaskSequence_Action Server WMI Class.
Enabled

Data type: BooleanAccess type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.
Message

Data type: StringAccess type: Read/WriteQualifiers: [AllowedLen("0-512")]A user-defined message for display in the reboot dialog box. The message length can be between 0 and 512 characters.
MessageTimeout

Data type: UInt32Access type: Read/WriteQualifiers: [VariableName("SMSRebootTimeout")]The number of seconds that a user-defined message is displayed to the user before the computer restarts. Specify 0 seconds (default) to indicate that no reboot message should be displayed. The task sequence variable that is associated with this property is SMSRebootTimeout. For more information, see the MSDN documentation for Operating System Deployment Task Sequence Variables.
Name

Data type: StringAccess type: Read/WriteQualifiers: [AllowedLen("1-100")]See SMS_TaskSequence_Action Server WMI Class.
SupportedEnvironment

Data type: StringAccess type: Read/WriteQualifiers: [Not_Null:ToInstance]See SMS_TaskSequence_Action Server WMI Class.
Target

Data type: StringAccess type: Read/WriteQualifiers: [Not_Null, CommandLineArg(1)]The operating system to use for reboot. Possible values are:
  • HD

  • WinPE

Timeout

Data type: UInt32Access type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.

Remarks

Class qualifiers for this class include:

[CommandLine("smsboot.exe /target:%1"),VariablePrefix("SMSReboot"),

ActionCategory("General,6,1"),ActionUI{"AdminUI.TaskSequenceEditor.dll", "Microsoft.ConfigurationManagement.AdminConsole.TaskSequenceEditor", "RebootComputerControl", "TaskSequenceOptionControl"}]

For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.

Requirements

Runtime Requirements

Development Requirements

See Also