In System Center 2012 Configuration Manager, you configure the Heartbeat Discovery settings by modifying the necessary site control file settings.

To configure Heartbeat Discovery

  1. Set up a connection to the SMS Provider.

  2. Make a connection to the Heartbeat Discovery section of the site control file by using the SMS_SCI_Component class.

  3. Loop through the array of available properties, making changes as needed.

  4. Commit the changes to the site control file.

Example

The following example sets the Heartbeat Discovery settings by using the SMS_SCI_Component class to connect to the site control file and change properties.

For information about calling the sample code, see Calling Configuration Manager Code Snippets.

Visual Basic Script  Copy Code
Sub ConfigureHeartbeatDiscoverySettings1(swbemServices, 				 _
										 swbemContext, 					_
										 siteCode, 						_
										 serverName, 					_
										 newHeartbeatSiteControlFileSchedule)

 
	' Load site control file and get the SMS_SITE_CONTROL_MANAGER section.
	swbemServices.ExecMethod "SMS_SiteControlFile.Filetype=1,Sitecode=""" & siteCode & """", "Refresh", , , swbemContext				 

	Query = "SELECT * FROM SMS_SCI_Component " & 					 _
	"WHERE ItemName = 'SMS_SITE_CONTROL_MANAGER|" & serverName & "' " &  _   
	"AND SiteCode = '" & siteCode & "'"
			
	' Get the SMS Software Update Point properties.
	Set SCIComponentSet = swbemServices.ExecQuery(Query, ,wbemFlagForwardOnly Or wbemFlagReturnImmediately, swbemContext)
					 
	' Only one instance is returned from the query.
	For Each SCIComponent In SCIComponentSet

		' Display the server name.
		wscript.echo "Server: " & SCIComponent.Name

		' Loop through the array of embedded SMS_EmbeddedProperty instances.
		For Each vProperty In SCIComponent.Props
		
			' Setting: Heartbeat Site Control File Schedule.
			If vProperty.PropertyName = "Heartbeat Site Control File Schedule" Then
				wscript.echo " "
				wscript.echo vProperty.PropertyName			 
				wscript.echo "Current value " &  vProperty.Value1   
			
				'Modify the value.
				vProperty.Value1 = newHeartbeatSiteControlFileSchedule
				wscript.echo "New value " & newHeartbeatSiteControlFileSchedule
			End If	
			
		 Next
		 
		 ' Update the component in your copy of the site control file. Get the path
		 ' to the updated object, which could be used later to retrieve the instance.
		Set SCICompPath = SCIComponent.Put_(wbemChangeFlagUpdateOnly, swbemContext)

	Next
					
	' Commit the change to the actual site control file.
	Set InParams = swbemServices.Get("SMS_SiteControlFile").Methods_("CommitSCF").InParameters.SpawnInstance_
	InParams.SiteCode = siteCode
	swbemServices.ExecMethod "SMS_SiteControlFile", "CommitSCF", InParams, , swbemContext

End Sub

' SEPARATE EXAMPLE TO ENABLE HEARTBEAT DISCOVERY ON THE CLIENT
Sub ConfigureHeartbeatDiscoverySettings2(swbemServices, 				 _
										 swbemContext, 					_
										 siteCode, 						_
										 enableDisableHeartbeatDDR)

	' Load site control file and get the SMS_SCI_ClientConfig section.
	swbemServices.ExecMethod "SMS_SiteControlFile.Filetype=1,Sitecode=""" & siteCode & """", "Refresh", , , swbemContext

	Query = "SELECT * FROM SMS_SCI_ClientConfig " &   _
	"WHERE ItemName  = 'Client Properties'" & _
	"AND SiteCode = '" & siteCode & "'" 

	 Set SCIComponentSet = swbemServices.ExecQuery(Query, ,wbemFlagForwardOnly Or wbemFlagReturnImmediately, swbemContext)   
					 
	' Only one instance is returned from the query.
	For Each SCIComponent In SCIComponentSet
 
		'Loop through the array of embedded SMS_EmbeddedProperty instances.
		For Each vProperty In SCIComponent.Props
		
			' Setting: Enable Heartbeat DDR
			If vProperty.PropertyName = "Enable Heartbeat DDR" Then
				wscript.echo " "
				wscript.echo vProperty.PropertyName
				wscript.echo "Current value " &  vProperty.Value			 
			
				'Modify the value.
				vProperty.Value = enableDisableHeartbeatDDR
				wscript.echo "New value " & enableDisableHeartbeatDDR
			End If		 
			 
		Next   

		' Update the component in your copy of the site control file. Get the path
		' to the updated object, which could be used later to retrieve the instance.
		Set SCICompPath = SCIComponent.Put_(wbemChangeFlagUpdateOnly, swbemContext)
	
	Next
					
	' Commit the change to the actual site control file.
	Set InParams = swbemServices.Get("SMS_SiteControlFile").Methods_("CommitSCF").InParameters.SpawnInstance_
	InParams.SiteCode = siteCode
	swbemServices.ExecMethod "SMS_SiteControlFile", "CommitSCF", InParams, , swbemContext

End Sub
C#  Copy Code
public void ConfigureHeartbeatDiscoverySettings(WqlConnectionManager connection,
												string siteCode,
												string serverName,
												string newHeartbeatSiteControlFileSchedule,
												string newEnableDisableHeartbeatDDR)
{


	try
	{
	// Change the Heartbeat Site Control File Schedule value.
	
		// Connect to SMS_SITE_CONTROL_MANAGER section of the site control file.
		 IResultObject siteDefinition = connection.GetInstance(@"SMS_SCI_Component.FileType=2,ItemType='Component',SiteCode='" + siteCode + "',ItemName='SMS_SITE_CONTROL_MANAGER|" + serverName + "'");

		// Temporary copy of the embedded properties.
		Dictionary<string, IResultObject> embeddedProperties = siteDefinition.EmbeddedProperties;
	 
		foreach (KeyValuePair<string, IResultObject> kvp in siteDefinition.EmbeddedProperties)
		{ 								 
			// Property: Heartbeat Site Control File Schedule
			if (kvp.Value.PropertyList["PropertyName"] == "Heartbeat Site Control File Schedule")
			{
				Console.WriteLine();
				Console.WriteLine(kvp.Value.PropertyList["PropertyName"]);
				Console.WriteLine("Current value: " + embeddedProperties["Heartbeat Site Control File Schedule"]["Value1"].StringValue);

				embeddedProperties["Heartbeat Site Control File Schedule"]["Value1"].StringValue = newHeartbeatSiteControlFileSchedule;
				Console.WriteLine("New value	: " + newHeartbeatSiteControlFileSchedule);
		}
	}

		// Store the settings that have changed.
		siteDefinition.EmbeddedProperties = embeddedProperties;

		// Save the settings. 
		siteDefinition.Put();

}
	catch (SmsException ex)
	{
		Console.WriteLine();
		Console.WriteLine("Failed. Error: " + ex.InnerException.Message);
}

   
	try
	{
	// Change the Enable Heartbeat DDR value.

		// Connect to SMS_SCI_ClientConfig section of the site control file.
	IResultObject siteDefinition = connection.GetInstance(@"SMS_SCI_ClientConfig.FileType=2,ItemType='Client Configuration',SiteCode='" + siteCode + "',ItemName='Client Properties'");

		// Create temporary working copy of embedded properties.
		Dictionary<string, IResultObject> embeddedProperties = siteDefinition.EmbeddedProperties;

		foreach (KeyValuePair<string, IResultObject> kvp in siteDefinition.EmbeddedProperties)
		{
			// Setting: Enable Heartbeat DDR
			if (kvp.Value.PropertyList["PropertyName"] == "Enable Heartbeat DDR")
			{
				Console.WriteLine();
				Console.WriteLine(kvp.Value.PropertyList["PropertyName"]);
				Console.WriteLine("Current value: " + kvp.Value.PropertyList["Value"]);
			
				// Change value using the newEnableDisableHeartbeatDDR value passed in. 
				embeddedProperties["Enable Heartbeat DDR"]["Value"].StringValue = newEnableDisableHeartbeatDDR;
				Console.WriteLine("New value	: " + newEnableDisableHeartbeatDDR);
		}				
	}

		// Store the settings that have changed.
		siteDefinition.EmbeddedProperties = embeddedProperties;

		// Save the settings. 
		siteDefinition.Put();
}

	catch (SmsException ex)
	{
		Console.WriteLine("Failed. Error: " + ex.InnerException.Message);
		throw;
}

}

The example method has the following parameters:

Parameter

Type

Description

  • connection

  • swbemServices

  • Managed: WqlConnectionManager

  • VBScript: SWbemServices

A valid connection to the SMS Provider.

swbemContext

  • VBScript: SWbemContext

A valid context object. For more information, see How to Add a Configuration Manager Context Qualifier by Using WMI.

siteCode

  • Managed: String

  • VBScript: String

The site code.

serverName

  • Managed: String

  • VBScript: String

The server name.

newHeartbeatSiteControlFileSchedule

  • Managed: String

  • VBScript: String

The schedule defining how often the client will produce heartbeat data discovery records (DDRs).

  • newEnableDisableHeartbeatDDR

  • enableDisableHeartbeatDDR

  • Managed: String

  • VBScript: String

A value to enable or disable the heartbeat DDR.

Disabled - 0

Enabled - 1

Compiling the Code

This C# example requires:

Namespaces

System

System.Collections.Generic

System.Text

Microsoft.ConfigurationManagement.ManagementProvider

Microsoft.ConfigurationManagement.ManagementProvider.WqlQueryEngine

Assembly

adminui.wqlqueryengine

microsoft.configurationmanagement.managementprovider

Robust Programming

For more information about error handling, see About Configuration Manager Errors.

Security

For more information about securing Configuration Manager applications, see Securing Configuration Manager Applications.

See Also