Value
specifies information to associate a Tablet
PC monitor to a digitizer.
This setting requires the string values of: DigitizerPattern, AdapterPattern, and MonitorPattern. For information about finding the Device String or Device ID values, see the MSDN® articles: DISPLAY_DEVICE and EnumDisplayDevices.
Note |
---|
Some portions of these patterns may change depending on installation order. For best results, only use portions of the string that are unique to the device. |
An association is made between the digitizer and monitor if:
- The DigitizerPattern matches exactly one digitizer.
- The combination of AdapterPattern and
MonitorPattern match exactly one monitor.
Values
"DigitizerPattern"="AdapterPattern|MonitorPattern" |
Specifies the information to associate the Tablet PC monitor to the digitizer. DigitizerPattern is a substring that matches the Device Instance Path of the digitizer. AdapterPattern is a substring that matches a unique pattern from either the DeviceString or DeviceID fields from DISPLAY_DEVICE. MonitorPattern is a substring that matches a unique pattern from either the DeviceString or DeviceID fields from DISPLAY_DEVICE. It is not required to match these string values completely. You can provide just the portions of the string that are unique to the device. |
This string type does not support empty elements. Do not create an empty value for this setting.
Valid Configuration Passes
offlineServicing
Parent Hierarchy
Applies To
For a list of the supported Windows® editions and architectures that this component supports, see Microsoft-Windows-TabletPC-Platform-Input-Core.
XML Example
The following XML output shows how to configure the
AssociationData
setting to associate a Tablet PC
monitor to three digitizers on the same system.
For the Tablet PC monitor in this example, the DeviceString is "MONITOR\FAB1234B\{12ab34cd56-ef76-ab54-3210fe}", and the DeviceID field is "Generic PnP Monitor". The substring FAB1234B is chosen for Monitor_pattern in the example, though other choices of unique substrings are also possible.
Note |
---|
In Windows System Image Manager, you can enter values with
quotation marks. In the XML, the quotation marks are replaced with
" . |
Copy Code | |
---|---|
<AssociationData> <AssociationElement wcm:action="add" wcm:keyValue="Monitor1">"hid#VID_1B96&PID_0008&REV_2100&mi_01&col01"="PCI\\VEN_8086&DEV_4102&SUBSYS_16B510CF|FUJ5812"</AssociationElement> <AssociationElement wcm:action="add" wcm:keyValue="Monitor2">"hid#VID_1B96&PID_0008&REV_2100&mi_01&col02"="PCI\\VEN_8086&DEV_4102&SUBSYS_16B510CF|FUJ5812"</AssociationElement> </AssociationData> <AssociationElement wcm:action="add" wcm:keyValue="Monitor3">"hid#VID_1B96&PID_0008&REV_2100&mi_01&col03"="PCI\\VEN_8086&DEV_4102&SUBSYS_16B510CF|FUJ5812"</AssociationElement> </AssociationData> |