The SMS_TaskSequence_ConvertDiskAction Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents a task sequence action that converts a physical disk from a basic disk type to a dynamic disk type.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Class SMS_TaskSequence_ConvertDiskAction : SMS_TaskSequence_Action
{
	SMS_TaskSequence_Condition Condition;
	Boolean ContinueOnError;
	String Description;
	UInt32 DiskIndex;
	Boolean Enabled;
	String Name;
	String SupportedEnvironment;
	UInt32 Timeout;
};

Methods

The SMS_TaskSequence_ConvertDiskAction class does not define any methods.

Properties

Condition


Data type: SMS_TaskSequence_ConditionAccess type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.
ContinueOnError


Data type: BooleanAccess type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.
Description


Data type: StringAccess type: Read/WriteQualifiers: [AllowedLen("0-255")]See SMS_TaskSequence_Action Server WMI Class.
DiskIndex


Data type: UInt32Access type: Read/WriteQualifiers: [Not_Null, VariableName("OSDConvertDiskIndex")]The physical disk number to convert. The task sequence variable associated with this property is OSDConvertDiskIndex. For more information, see the MSDN documentation for Operating System Deployment Task Sequence Variables.
Enabled


Data type: BooleanAccess type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.
Name


Data type: StringAccess type: Read/WriteQualifiers: [AllowedLen("1-100")]See SMS_TaskSequence_Action Server WMI Class.
SupportedEnvironment


Data type: StringAccess type: Read/WriteQualifiers: [Not_Null:ToInstance]See SMS_TaskSequence_Action Server WMI Class.
Timeout


Data type: UInt32Access type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.

Remarks

Class qualifiers for this class include:

[CommandLine("osddiskpart.exe convert %%OSDConvertDiskIndex%%"),

VariablePrefix("OSD"),ActionCategory{"Disks,2,2"},

ActionUI{"AdminUI.TaskSequenceEditor.dll", "Microsoft.ConfigurationManagement.AdminConsole.TaskSequenceEditor", "ConvertDiskToDynamicControl", "TaskSequenceOptionControl"}]

For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.

Requirements

Runtime Requirements

Development Requirements

See Also


Send comments about this topic to Microsoft.