The SMS_CIAssignmentBaseClass Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that serves as an abstract base class for the SMS_BaselineAssignment Server WMI Class and SMS_UpdatesAssignment Server WMI Class.
Class SMS_CIAssignmentBaseClass : SMS_BaseClass { Boolean ApplyToSubTargets; SInt32 AssignedCIs[]; SInt32 AssignmentAction; String AssignmentDescription; SInt32 AssignmentID; String AssignmentName; String AssignmentUniqueID; DateTime CreationTime; SInt32 DesiredConfigType; Boolean DisableMomAlerts; UInt32 DPLocality; DateTime EnforcementDeadline; String EvaluationSchedule; DateTime ExpirationTime; DateTime LastModificationTime; UInt32 LocaleID; Boolean LogComplianceToWinEvent; SInt32 NonComplianceCriticality; Boolean NotifyUser; Boolean OverrideServiceWindows; Boolean RaiseMomAlertsOnFailure; Boolean ReadOnly; Boolean RebootOutsideOfServiceWindows; Boolean SendDetailedNonComplianceStatus; String SourceSite; DateTime StartTime; UInt32 SuppressReboot; String TargetCollectionID; Boolean UseGMTTimes; Boolean WoLEnabled; }; |
Methods
The SMS_CIAssignmentBaseClass class does not define any methods.
Properties
- ApplyToSubTargets
- Data type: BooleanAccess type: Read/WriteQualifiers: [not_null]true to apply the configuration item assignment to a subcollection.
- AssignedCIs
- Data type: SInt32 ArrayAccess type: Read/WriteQualifiers: [not_null]Array of IDs for the configuration items targeted by the assignment.
- AssignmentAction
- Data type: SInt32Access type: Read/WriteQualifiers:
[not_null]Action associated with the configuration item assignment.
Possible values are:
1
DETECT
2
APPLY
- AssignmentDescription
- Data type: StringAccess type: Read/WriteQualifiers: NoneThe description of the configuration item assignment.
- AssignmentID
- Data type: SInt32Access type: Read/WriteQualifiers: [key]The ID of the configuration item assignment. This ID is unique only for the site.
- AssignmentName
- Data type: StringAccess type: Read/WriteQualifiers: [not_null]The local assignment name.
- AssignmentUniqueID
- Data type: StringAccess type: Read-onlyQualifiers: [read, not_null]The unique ID of the configuration item assignment. This ID is unique across sites.
- ContainsExpiredUpdates
- Data type: BooleanAccess type: Read-onlyQualifiers: [read, not_null] true if the deployment contains one or more expired updates.
- CreationTime
- Data type: DateTimeAccess type: Read-onlyQualifiers: [read, not_null]The date and time when the configuration item assignment is created.
- DesiredConfigType
- Data type: SInt32Access type: Read/WriteQualifiers:
[not_null]The type of the configuration item. Possible values are:
1
REQUIRED
2
NOT_ALLOWED
- DisableMomAlerts
- Data type: BooleanAccess type: Read/WriteQualifiers: Nonetrue if the client is configured to raise MOM alerts when a configuration item is applied. The default is false.
- DPLocality
- Data type: UInt32Access type: Read/WriteQualifiers:
[not_null, bits]Flags that determine how the client obtains
distribution points, according to distribution point locality.
Possible values are:
- 4
- DP_DOWNLOAD_FROM_LOCAL
- 6
- DP_DOWNLOAD_FROM_REMOTE
- 17
- DP_NO_FALLBACK_UNPROTECTED
- EnforcementDeadline
- Data type: DateTimeAccess type: Read/WriteQualifiers: NoneThe date and time when the configuration item assignment will be enforced.
- EvaluationSchedule
- Data type: StringAccess type: Read/WriteQualifiers: NoneThe assignment evaluation schedule.
- ExpirationTime
- Data type: DateTimeAccess type: Read/WriteQualifiers: NoneThe date and time when the configuration item assignment expires.
- LastModificationTime
- Data type: DateTimeAccess type: Read-onlyQualifiers: [read, not_null]Date and time when the configuration item assignment was last modified.
- LocaleID
- Data type: UInt32Access type: Read-onlyQualifiers: [read, not_null]ID for the locale of the assignment name and assignment description properties.
- LogComplianceToWinEvent
- Data type: BooleanAccess type: Read/WriteQualifiers: [not_null]true to log compliance status to Windows event logs. The default value is false.
- NonComplianceCriticality
- Data type: SInt32Access type: Read/WriteQualifiers: NoneThe configuration item non-compliance criticality for the assignment.
- NotifyUser
- Data type: BooleanAccess type: Read/WriteQualifiers: [not_null]true to notify the user when a configuration item is available.
- OverrideServiceWindows
- Data type: BooleanAccess type: Read/WriteQualifiers: Nonetrue it the client ignores maintenance windows when a configuration item is applied.
- RaiseMomAlertsOnFailure
- Data type: BooleanAccess type: Read/WriteQualifiers: Nonetrue if the client raises MOM alerts if it fails to apply a configuration item. The default is false.
- ReadOnly
- Data type: BooleanAccess type: Read-onlyQualifiers: [read, not_null]The assignment is read-only.
- RebootOutsideOfServiceWindows
- Data type: BooleanAccess type: Read/WriteQualifiers: Nonetrue if the client reboots outside a maintenance window if a reboot is pending after applying a configuration item targeted by the assignment.
- SendDetailedNonComplianceStatus
- Data type: BooleanAccess type: Read/WriteQualifiers: [not_null]true to send a detailed non-compliance status message. The default is false.
- SourceSite
- Data type: StringAccess type: Read-onlyQualifiers: [read, not_null]The site code of the site where the assignment was created.
- StartTime
- Data type: DateTimeAccess type: Read/WriteQualifiers: [not_null]The date and time when the configuration item assignment was initially offered.
- SuppressReboot
- Data type: UInt32Access type: Read/WriteQualifiers:
[not_null, bits]Value indicating whether the client should not
reboot the computer, if there is a reboot pending after the
configuration item is applied. Possible values are:
0
SUPPRESS_REBOOT_WORKSTATIONS
1
SUPPRESS_REBOOT_SERVERS
- TargetCollectionID
- Data type: StringAccess type: Read/WriteQualifiers: [not_null]The ID of the collection to which the assignment is targeted.
- UseGMTTimes
- Data type: BooleanAccess type: Read/WriteQualifiers: [not_null]true if the times and schedules are in Universal Coordinated Time (UTC).
- WoLEnabled
- Data type: BooleanAccess type: Read/WriteQualifiers: Nonetrue to send a Wake On Lan (WoL) transmission to the client when the deadline is reached for the assignment.
Remarks
Class qualifiers for this class include:
- Abstract
For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.
Requirements
Runtime Requirements
For more information, see Configuration Manager Server Runtime Requirements.
Development Requirements
For more information, see Configuration Manager Server Development Requirements.
See Also
Reference
SMS_BaselineAssignment Server WMI ClassOther Resources
Configuration Manager Desired Configuration ManagementSend comments about this topic to Microsoft.