The SMS_TaskSequence_SetVariableAction Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents a task sequence action that sets the value of a task sequence environment variable.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Class SMS_TaskSequence_SetVariableAction : SMS_TaskSequence_Action
{
	SMS_TaskSequence_Condition Condition;
	Boolean ContinueOnError;
	String Description;
	Boolean Enabled;
	String Name;
	String SupportedEnvironment;
	UInt32 Timeout;
	String VariableName;
	String VariableValue;
};

Methods

The SMS_TaskSequence_SetVariableAction class does not define any methods.

Properties

Condition

Data type: SMS_TaskSequence_ConditionAccess type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.
ContinueOnError

Data type: BooleanAccess type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.
Description

Data type: StringAccess type: Read/WriteQualifiers: [AllowedLen("0-255")]See SMS_TaskSequence_Action Server WMI Class.
Enabled

Data type: BooleanAccess type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.
Name

Data type: StringAccess type: Read/WriteQualifiers: [AllowedLen("1-100")]See SMS_TaskSequence_Action Server WMI Class.
SupportedEnvironment

Data type: StringAccess type: Read/WriteQualifiers: [Not_Null:ToInstance]See SMS_TaskSequence_Action Server WMI Class.
Timeout

Data type: UInt32Access type: Read/WriteQualifiers: NoneSee SMS_TaskSequence_Action Server WMI Class.
VariableName

Data type: StringAccess type: Read/WriteQualifiers: [CommandLineArg(1), Not_Null, AllowedLen("1-256")]Name of the task sequence environment variable to set. The name length must be between 1 and 256 characters.
VariableValue

Data type: StringAccess type: Read/WriteQualifiers: [CommandLineArg(2), Not_Null, AllowedLen("0-4001")]Value of the task sequence environment variable. The value length must be between 0 and 4,001 characters.

Remarks

Class qualifiers for this class include:

[CommandLine("tsenv.exe \"%1=%2\""),

ActionCategory{"General,7,1"},ActionUI{"AdminUI.TaskSequenceEditor.dll", "Microsoft.ConfigurationManagement.AdminConsole.TaskSequenceEditor", "SetSequenceVariableControl", "TaskSequenceOptionControl"}]

For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.

Requirements

Runtime Requirements

Development Requirements