The SMS_ConfigurationPolicyAssignment Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents the deployment of an instance of SMS_ConfigurationPolicy. It is similar to SMS_BaselineAssignment, except that SMS_ConfigurationPolicy is deployed directly, instead of being collected into a baseline first.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Class SMS_ConfigurationPolicyAssignment : SMS_CIAssignmentBaseClass
{
	Boolean ApplyToSubTargets;
	String AssignedCI_UniqueID;
	SInt32 AssignedCIs[];
	SInt32 AssignmentAction;
	String AssignmentDescription;
	SInt32 AssignmentID;
	String AssignmentName;
	SInt32 AssignmentType;
	String AssignmentUniqueID;
	Boolean ContainsExpiredUpdates;
	DateTime CreationTime;
	SInt32 DesiredConfigType;
	Boolean DisableMomAlerts;
	UInt32 DPLocality;
	Boolean Enabled;
	DateTime EnforcementDeadline;
	Boolean EnforcementEnabled;
	String EvaluationSchedule;
	DateTime ExpirationTime;
	DateTime LastModificationTime;
	String LastModifiedBy;
	Boolean LimitStateMessageVerbosity;
	UInt32 LocaleID;
	Boolean LogComplianceToWinEvent;
	SInt32 NonComplianceCriticality;
	Boolean NotifyUser;
	Boolean OverrideServiceWindows;
	Boolean PersistOnWriteFilterDevices;
	Boolean RaiseMomAlertsOnFailure;
	UInt32 RandomizationMinutes;
	Boolean RebootOutsideOfServiceWindows;
	Boolean SendDetailedNonComplianceStatus;
	String SourceSite;
	DateTime StartTime;
	UInt32 StateMessagePriority;
	UInt32 StateMessageVerbosity;
	UInt32 SuppressReboot;
	String TargetCollectionID;
	Boolean UseGMTTimes;
	Boolean UserUIExperience;
	Boolean WoLEnabled;
};

Methods

The SMS_ConfigurationPolicyAssignment class does not define any methods.

Properties

ApplyToSubTargets

Data type: BooleanAccess type: Read/Write Qualifiers: [deprecated]See SMS_CIAssignmentBaseClass Server WMI Class
AssignedCI_UniqueID

Data type: StringAccess type: Read-only Qualifiers: [not_null, read]Unique identifier of the assigned baseline configuration item.
AssignedCIs

Data type: SInt32 Array Access type: Read/Write Qualifiers: [not_null]See SMS_CIAssignmentBaseClass Server WMI Class
AssignmentAction

Data type: SInt32Access type: Read/Write Qualifiers: [enumeration, not_null]See SMS_CIAssignmentBaseClass Server WMI Class
AssignmentDescription

Data type: StringAccess type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class.
AssignmentID

Data type: SInt32Access type: Read/Write Qualifiers: [key, key]See SMS_CIAssignmentBaseClass Server WMI Class
AssignmentName

Data type: StringAccess type: Read/Write Qualifiers: [not_null]See SMS_CIAssignmentBaseClass Server WMI Class
AssignmentType

Data type: SInt32Access type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class
AssignmentUniqueID

Data type: StringAccess type: Read-only Qualifiers: [not_null, read]See SMS_CIAssignmentBaseClass Server WMI Class
ContainsExpiredUpdates

Data type: BooleanAccess type: Read-only Qualifiers: [not_null, read]See SMS_CIAssignmentBaseClass Server WMI Class
CreationTime

Data type: DateTimeAccess type: Read-only Qualifiers: [not_null, read]See SMS_CIAssignmentBaseClass Server WMI Class
DesiredConfigType

Data type: SInt32Access type: Read/Write Qualifiers: [enumeration, not_null]See SMS_CIAssignmentBaseClass Server WMI Class
DisableMomAlerts

Data type: BooleanAccess type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class
DPLocality

Data type: UInt32Access type: Read/Write Qualifiers: [bits, not_null]See SMS_CIAssignmentBaseClass Server WMI Class
Enabled

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null]See SMS_CIAssignmentBaseClass Server WMI Class
EnforcementDeadline

Data type: DateTimeAccess type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class
EnforcementEnabled

Data type: BooleanAccess type: Read/Write Qualifiers: noneSee SMS_BaselineAssignment Server WMI Class.
EvaluationSchedule

Data type: StringAccess type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class
ExpirationTime

Data type: DateTimeAccess type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class
LastModificationTime

Data type: DateTimeAccess type: Read-only Qualifiers: [not_null, read]See SMS_CIAssignmentBaseClass Server WMI Class
LastModifiedBy

Data type: StringAccess type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class
LimitStateMessageVerbosity

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null, obsoleted]This method/property has been removed or deprecated in System Center 2012 R2 Configuration Manager SP1.
LocaleID

Data type: UInt32Access type: Read-only Qualifiers: [not_null, read]See SMS_CIAssignmentBaseClass Server WMI Class
LogComplianceToWinEvent

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null]See SMS_CIAssignmentBaseClass Server WMI Class
NonComplianceCriticality

Data type: SInt32Access type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class
NotifyUser

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null]See SMS_CIAssignmentBaseClass Server WMI Class
OverrideServiceWindows

Data type: BooleanAccess type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class
PersistOnWriteFilterDevices

Data type: BooleanAccess type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class
RaiseMomAlertsOnFailure

Data type: BooleanAccess type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class
RandomizationMinutes

Data type: UInt32Access type: Read/Write Qualifiers: noneRandom time in minutes that is used when evaluating an assignment automatically once it arrives at the client. The random evaluation interval distributes the processing load when multiple assignments arrive at the client at same time.
RebootOutsideOfServiceWindows

Data type: BooleanAccess type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class
SendDetailedNonComplianceStatus

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null]See SMS_CIAssignmentBaseClass Server WMI Class
SourceSite

Data type: StringAccess type: Read-only Qualifiers: [not_null, read]See SMS_CIAssignmentBaseClass Server WMI Class
StartTime

Data type: DateTimeAccess type: Read/Write Qualifiers: [not_null]See SMS_CIAssignmentBaseClass Server WMI Class
StateMessagePriority

Data type: UInt32Access type: Read/Write Qualifiers: [valuemap, values]See SMS_CIAssignmentBaseClass Server WMI Class
StateMessageVerbosity

Data type: UInt32Access type: Read/Write Qualifiers: [enumeration]See SMS_UpdateGroupAssignment Server WMI Class.
SuppressReboot

Data type: UInt32Access type: Read/Write Qualifiers: [bits, not_null]See SMS_CIAssignmentBaseClass Server WMI Class
TargetCollectionID

Data type: StringAccess type: Read/Write Qualifiers: [not_null]See SMS_CIAssignmentBaseClass Server WMI Class
UseGMTTimes

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null]See SMS_CIAssignmentBaseClass Server WMI Class
UserUIExperience

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null]true if user notification is displayed; otherwise, false.
WoLEnabled

Data type: BooleanAccess type: Read/Write Qualifiers: noneSee SMS_CIAssignmentBaseClass Server WMI Class

Remarks

Requirements

Runtime Requirements

Development Requirements