The SMS_ConfigurationBaselineInfo Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents a baseline configuration item. For more information about this type of configuration item, see SMS_BaselineAssignment Server WMI Class.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Class SMS_ConfigurationBaselineInfo : SMS_ConfigurationItemBaseClass
{
	UInt32 ActivatedCount;
	String ApplicabilityCondition;
	UInt32 AssignedCount;
	String CategoryInstance_UniqueIDs[];
	UInt32 CI_ID;
	String CI_UniqueID;
	UInt32 CIType_ID;
	UInt32 CIVersion;
	UInt32 ComplianceCount;
	Real64 CompliantPercentage; 
	String CreatedBy;
	DateTime DateCreated;
	DateTime DateLastModified;
	DateTime EffectiveDate;
	UInt32 EULAAccepted;
	Boolean EULAExists;
	DateTime EULASignoffDate;
	String EULASignoffUser;
	UInt32 ExecutionContext;
	UInt32 FailureCount;
	Boolean InUse;
	Boolean IsAssigned;
	Boolean IsBroken; 
	Boolean IsBundle;
	Boolean IsDigest;
	Boolean IsEnabled;
	Boolean IsExpired;
	Boolean IsHidden;
	Boolean IsLatest; 
	Boolean IsQuarantined;
	Boolean IsSuperseded;
	Boolean IsUserDefined;
	String LastModifiedBy;
	String LocalizedCategoryInstanceNames[];
	String LocalizedDescription;
	String LocalizedDisplayName;
	String LocalizedInformativeURL;
	UInt32 LocalizedPropertyLocaleID;
	UInt32 ModelID; 
	String ModelName;
	UInt32 NonComplianceCount;
	UInt32 PermittedUses; 
	String PlatformCategoryInstance_UniqueIDs[];
	UInt32 PlatformType;
	SMS_SDMPackageLocalizedData SDMPackageLocalizedData[];
	UInt32 SDMPackageVersion;
	String SDMPackageXML;
	String SecuredScopeNames[];
	String SedoObjectVersion;
	UInt32 Severity;
	String SourceSite; 
	Real64 TargetCompliance;
};

Methods

The SMS_ConfigurationBaselineInfo class does not define any methods.

Properties

ActivatedCount

Data type: UInt32Access type: ReadQualifiers: NoneThe number of computers that have evaluated the configuration item.
ApplicabilityCondition

Data type: StringAccess type: ReadQualifiers: [SizeLimit("512"), not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
AssignedCount

Data type: UInt32Access type: ReadQualifiers: NoneThe number of computers that are targeted with the configuration item.
CategoryInstance_UniqueIDs

Data type: String ArrayAccess type: ReadQualifiers: NoneSee SMS_ConfigurationItemLatestBaseClass Server WMI Class.
CI_ID

Data type: UInt32Access type: ReadQualifiers: [key]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
CI_UniqueID

Data type: StringAccess type: ReadQualifiers:[unique, not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
CIType_ID

Data type: UInt32Access type: Read-onlyQualifiers: [not_null, read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class..For this class, the type ID is Baseline (2).
CIVersion

Data type: UInt32Access type: Read-onlyQualifiers: [read, not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
ComplianceCount

Data type: UInt32Access type: ReadQualifiers: NoneNumber of computers that are compliant with the configuration item.
CompliantPercentage

Data type: Real64Access type: Read/Write Qualifiers: noneThe property is deprecated. Use the information contained in the SMS_DeploymentSummary Server WMI Class instead.
CreatedBy

Data type: StringAccess type: Read-onlyQualifiers: [SizeLimit("512"), read, not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
DateCreated

Data type: DateTimeAccess type: Read-onlyQualifiers: [read, not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
DateLastModified

Data type: DateTimeAccess type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
EffectiveDate

Data type: DateTimeAccess type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
EULAAccepted

Data type: UInt32Access type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
EULAExists

Data type: BooleanAccess type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
EULASignoffDate

Data type: DateTimeAccess type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
EULASignoffUser

Data type: StringAccess type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
ExecutionContext

Data type: UInt32Access type: Read-only Qualifiers: [read, valuemap, values]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
FailureCount

Data type: UInt32Access type: ReadQualifiers: NoneNumber of computers that failed to evaluate the configuration item.
InUse

Data type: BooleanAccess type: Read/Write Qualifiers: nonetrue if the configuration item is in use. A configuration item is used, if it is referenced by other baseline or its setting is referenced by other configuration item.
IsAssigned

Data type: BooleanAccess type: ReadQualifiers: Nonetrue if the configuration item is assigned. The default value is false.
IsBundle

Data type: BooleanAccess type: ReadQualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsBroken

Data type: BooleanAccess type: Read-only Qualifiers: [read]true if the configuration item is broken, otherwise, the value is false.
IsDigest

Data type: BooleanAccess type: Read-onlyQualifiers: [read, lazy]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsEnabled

Data type: BooleanAccess type: ReadQualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsExpired

Data type: BooleanAccess type: ReadQualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsHidden

Data type: BooleanAccess type: ReadQualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsLatest

Data type: BooleanAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsQuarantined

Data type: BooleanAccess type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.This property is not used for desired configuration management.
IsSuperseded

Data type: BooleanAccess type: Read-onlyQualifiers: [read, not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsUserDefined

Data type: BooleanAccess type: ReadQualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LastModifiedBy

Data type: StringAccess type: Read-onlyQualifiers: [SizeLimit("512"), read, not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LocalizedCategoryInstanceNames

Data type: String ArrayAccess type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LocalizedDescription

Data type: StringAccess type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LocalizedDisplayName

Data type: StringAccess type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LocalizedInformativeURL

Data type: StringAccess type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LocalizedPropertyLocaleID

Data type: UInt32Access type: Read-onlyQualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
ModelID

Data type: UInt32Access type: Read/Write Qualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
ModelName

Data type: StringAccess type: ReadQualifiers: [unique, not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
NonComplianceCount

Data type: UInt32Access type: ReadQualifiers: NoneNumber of computers that are not compliant with the configuration item.
PermittedUses

Data type: UInt32Access type: ReadQualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
PlatformCategoryInstance_UniqueIDs

Data type: String Array Access type: Read/Write Qualifiers: noneSee SMS_ConfigurationItemLatestBaseClass Server WMI Class.
PlatformType

Data type: UInt32Access type: Read-only Qualifiers: [bitmap, bitvalues, read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
SDMPackageLocalizedData

Data type: SMS_SDMPackageLocalizedData ArrayAccess type: ReadQualifiers: [lazy]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
SDMPackageVersion

Data type: UInt32Access type: ReadQualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
SDMPackageXML

Data type: StringAccess type: ReadQualifiers: [lazy]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
SecuredScopeNames

Data type: String Array Access type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
SedoObjectVersion

Data type: StringAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
Severity

Data type: UInt32Access type: ReadQualifiers: NoneThe noncompliance severity of the configuration item.
SourceSite

Data type: StringAccess type: ReadQualifiers: [SizeLimit("3")]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
TargetCompliance

Data type: Real64Access type: Read/Write Qualifiers: noneThe property is deprecated. Use the information contained in the SMS_DeploymentSummary Server WMI Class class instead.

Remarks

Class qualifiers for this class include:

  • Secured

  • Read (read-only)

For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.

Your application can use this class to create a baseline. After creating the object, the application should set the CIType_ID property to Baseline (2). When the object is properly configured, the application can use the SMS_BaselineAssignment Server WMI Class class to populate it with other configuration items and corresponding rules.

For information on the use of this class, see How to List Configuration Assignments and How to Assign Configuration Baselines. An example for baseline configuration is provided in Configuration Baseline Example 1.

Requirements

Runtime Requirements

Development Requirements

See Also