The SMS_Report Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents a fully defined report that can be run by Configuration Manager Reports.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Class SMS_Report : SMS_BaseClass
{
	String Category;
	String Comment;
	UInt32 DrillThroughColumns[];
	UInt32 DrillThroughReportID;
	ref:SMS_Report DrillThroughReportPath;
	String DrillThroughURL;
	String GraphCaption;
	UInt32 GraphType;
	UInt32 GraphXCol;
	UInt32 GraphYCol;
	Boolean MachineDetail;
	Boolean MachineSource;
	String Name;
	UInt32 NumPrompts;
	UInt32 RefreshInterval;
	String ReportGUID;
	UInt32 ReportID;
	SMS_ReportParameter ReportParams[];
	String SecurityKey;
	String SQLQuery;
	Boolean StatusMessageDetailSource;
	Boolean UnicodeData;
	String XColLabel;
	String YColLabel;
};

Methods

The following table shows the methods in SMS_Report.

Method Description

GetReportPointInfo Method in Class SMS_Report

Gets report point information.

ValidateQuery Method in Class SMS_Report

Verifies that a report query is a valid SQL statement and performs the same level of validation that occurs when the report is saved.

Properties

Category

Data type: StringAccess type: Read/WriteQualifiers: NoneCategory to be used in the Configuration Manager console to filter the list of reports and to provide a report hierarchy. The default value is "".
Comment

Data type: StringAccess type: Read/WriteQualifiers: NoneFurther description of the report to be displayed on the property page for the report in the Configuration Manager console.
DrillThroughColumns

Data type: UInt32 ArrayAccess type: Read/WriteQualifiers: NoneIntegers indicating the columns to use as the parameters of the destination report when drilling through on a particular row. If this property is not applicable, set it to null or an empty array.
DrillThroughReportID

Data type: UInt32Access type: Read/WriteQualifiers: NoneReport ID to link to each row of the report. Selected columns from the originating report are used as parameters to the destination report. Set this property to null if there is no drill-through destination for the report. This property can be set to a report object path to support references to other reports in the same MOF file as the originating report.
DrillThroughReportPath

Data type: SMS_Report REFAccess type: Read OnlyQualifiers: [lazy]Relative path of the WMI object representing the destination report to which the originating report will drill through. When defining multiple reports in a MOF file that link together, set this property to the path alias from the previously defined drill-through report.
DrillThroughURL

Data type: StringAccess type: Read/WriteQualifiers: NoneThe URL of the drill-through report.
GraphCaption

Data type: StringAccess type: Read/WriteQualifiers: NoneCaption for the report graph. If there is no graph, set this property to null.
GraphType

Data type: UInt32Access type: Read/WriteQualifiers: NoneType of report graph. Set this property to null if no graph is available.
GraphXCol

Data type: UInt32Access type: Read/WriteQualifiers: NoneColumn number to use for the X axis of the graph. Set this property to null if it is not applicable.
GraphYCol

Data type: UInt32Access type: Read/WriteQualifiers: NoneColumn number to use for the Y axis of the graph. Set this property to null if it is not applicable.
MachineDetail

Data type: BooleanAccess type: Read/WriteQualifiers: Nonetrue if the report is a computer detail report, having one parameter that represents the Name0 column of the report. The default value is false.
MachineSource

Data type: BooleanAccess type: Read/WriteQualifiers: Nonetrue if this report drills through to the computer details page. The DrillThroughColumns property should contain a single index representing the Name0 column of the report. The default value is false.
Name

Data type: StringAccess type: Read/WriteQualifiers: NoneReport name to display in the Configuration Manager console and on the report itself.
NumPrompts

Data type: UInt32Access type: Read/WriteQualifiers: NoneThe number of report prompts allowed in the console.
RefreshInterval

Data type: UInt32Access type: Read/WriteQualifiers: [Range("0-60")]The interval, in seconds, that should elapse before the report is automatically rerun and the page is refreshed. Possible values are 0 (default) through 60. Set this property to 0 if the page should not be automatically refreshed.
ReportGUID

Data type: StringAccess type: Read/WriteQualifiers: [unique]GUID for the report.
ReportID

Data type: UInt32Access type: Read/WriteQualifiers: [key]Unique automatically generated number that identifies the report.
ReportParams

Data type: SMS_ReportParameter ArrayAccess type: Read/WriteQualifiers: [lazy]SMS_ReportParameter Server WMI Class objects that define the user-supplied parameters to the report. Set this property to null or an empty array if there are no parameters.
SecurityKey

Data type: StringAccess type: Read/WriteQualifiers: [unique]Unique automatically generated key used as the security identifier for the SMS_UserInstancePermissions Server WMI Class class.
SQLQuery

Data type: StringAccess type: Read/WriteQualifiers: [lazy, large]Text of the SQL query that produces the result set of the report.
StatusMessageDetailSource

Data type: BooleanAccess type: Read/WriteQualifiers: Nonetrue if the source of the status message is detailed. The default value is false.
UnicodeData

Data type: BooleanAccess type: Read/WriteQualifiers: Nonetrue if the report includes Unicode data. The default value is false.
XColLabel

Data type: StringAccess type: Read/WriteQualifiers: NoneCaption for the X axis of the graph. Set this property to null if it is not applicable.
YColLabel

Data type: StringAccess type: Read/WriteQualifiers: NoneCaption for the Y axis of the graph. Set this property to null if it is not applicable.

Remarks

Class qualifiers for this class include:

  • Secured

For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.

Requirements

Runtime Requirements

Development Requirements

See Also