The SMS_Application Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents an application.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Class SMS_Application : SMS_ConfigurationItemBaseClass
{
	String ApplicabilityCondition;
	String CategoryInstance_UniqueIDs[];
	UInt32 CI_ID;
	String CI_UniqueID;
	UInt32 CIType_ID;
	UInt32 CIVersion;
	String CreatedBy;
	DateTime DateCreated;
	DateTime DateLastModified;
	DateTime EffectiveDate;
	UInt32 EULAAccepted;
	Boolean EULAExists;
	DateTime EULASignoffDate;
	String EULASignoffUser;
	UInt32 ExecutionContext;
	UInt32 Featured;
	Boolean HasContent;
	Boolean IsBundle;
	Boolean IsDeployable;
	Boolean IsDeployed;
	Boolean IsDigest;
	Boolean IsEnabled;
	Boolean IsExpired;
	Boolean IsHidden;
	Boolean IsLatest;
	Boolean IsQuarantined;
	Boolean IsSuperseded;
	Boolean IsSuperseding;
	Boolean IsUserDefined;
	String LastModifiedBy;
	String LocalizedCategoryInstanceNames[];
	String LocalizedDescription;
	String LocalizedDisplayName;
	String LocalizedInformativeURL;
	UInt32 LocalizedPropertyLocaleID;
	UInt32 LogonRequirement;
	String Manufacturer;
	String ModelName;
	UInt32 ModelID; 
	UInt32 NumberOfDependentDTs;
	UInt32 NumberOfDependentTS;
	UInt32 NumberOfDeployments;
	UInt32 NumberOfDeploymentTypes;
	UInt32 NumberOfDevicesWithApp;
	UInt32 NumberOfDevicesWithFailure;
	UInt32 NumberOfUsersWithApp;
	UInt32 NumberOfUsersWithFailure;
	UInt32 NumberOfUsersWithRequest;
	UInt32 NumberOfVirtualEnvironments;
	String PackageID;
	UInt32 PermittedUses;
	String PlatformCategoryInstance_UniqueIDs[];
	UInt32 PlatformType;
	SMS_SDMPackageLocalizedData SDMPackageLocalizedData[];
	UInt32 SDMPackageVersion;
	String SDMPackageXML;
	String SecuredScopeNames[];
	String SedoObjectVersion;
	String SoftwareVersion;
	UInt32 SourceCIVersion;
	String SourceModelName;
	String SourceSite;
	DateTime SummarizationTime;
};

Methods

The following table lists the methods in the SMS_Application class.

Method Description

GetCIDocumentBody Method in Class SMS_Application

Gets the configuration item document body.

GetCIDocuments Method in Class SMS_Application

Gets all of the configuration item documents for the application installation.

Restore Method in Class SMS_Application

Restores this application and related deployment type as a current active application.

SetIsExpired Method in Class SMS_Application

Sets the expired status of this application.

UpdateStats Method in Class SMS_Application

Updates the statistics for this application.

Properties

ApplicabilityCondition

Data type: StringAccess type: Read/Write Qualifiers: [not_null, sizelimit]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
CategoryInstance_UniqueIDs

Data type: String Array Access type: Read/Write Qualifiers: noneSee SMS_ConfigurationItemLatestBaseClass Server WMI Class.
CI_ID

Data type: UInt32Access type: Read/Write Qualifiers: [key, key]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
CI_UniqueID

Data type: StringAccess type: Read/Write Qualifiers: [not_null, unique]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
CIType_ID

Data type: UInt32Access type: Read-only Qualifiers: [enumeration, not_null, read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
CIVersion

Data type: UInt32Access type: Read-only Qualifiers: [not_null, read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
CreatedBy

Data type: StringAccess type: Read-only Qualifiers: [not_null, read, sizelimit]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
DateCreated

Data type: DateTimeAccess type: Read-only Qualifiers: [not_null, read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
DateLastModified

Data type: DateTimeAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
EffectiveDate

Data type: DateTimeAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
EULAAccepted

Data type: UInt32Access type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
EULAExists

Data type: BooleanAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
EULASignoffDate

Data type: DateTimeAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
EULASignoffUser

Data type: StringAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
ExecutionContext

Data type: UInt32Access type: Read-only Qualifiers: [read, valuemap, values]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.If any of the contained deployment type of dependent deployment types is user context, this application is user context.

0

System

1

User

Featured

Data type: UInt32Access type: Read-only Qualifiers: [read]If the application is marked as a featured application, this will be 1. The default value is 0.
HasContent

Data type: BooleanAccess type: Read-only Qualifiers: [read]true if this application has content; otherwise, false.
IsBundle

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsDeployable

Data type: BooleanAccess type: Read-only Qualifiers: [read]true if the application can be deployed; otherwise, false. The application can be deployed if it contains an enabled deployment type.
IsDeployed

Data type: BooleanAccess type: Read-only Qualifiers: [read]true if the application has been deployed to client; otherwise, false. An application is deployed if there is assignment that assigns this application to any collection.
IsDigest

Data type: BooleanAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsEnabled

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsExpired

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsHidden

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsLatest

Data type: BooleanAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsQuarantined

Data type: BooleanAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsSuperseded

Data type: BooleanAccess type: Read-only Qualifiers: [not_null, read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class..
IsSuperseding

Data type: BooleanAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
IsUserDefined

Data type: BooleanAccess type: Read/Write Qualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LastModifiedBy

Data type: StringAccess type: Read-only Qualifiers: [not_null, read, sizelimit]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LocalizedCategoryInstanceNames

Data type: String ArrayAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LocalizedDescription

Data type: StringAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LocalizedDisplayName

Data type: StringAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LocalizedInformativeURL

Data type: StringAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LocalizedPropertyLocaleID

Data type: UInt32Access type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
LogonRequirement

Data type: UInt32Access type: Read-only Qualifiers: [enumeration, read]Requirement for user logon to setup. Possible values are:

0

Others

1

LogonRequired

Manufacturer

Data type: StringAccess type: Read-only Qualifiers: [read]Manufacturer of the application.
ModelName

Data type: StringAccess type: Read/Write Qualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
ModelID

Data type: UInt32Access type: Read/Write Qualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
NumberOfDependentDTs

Data type: UInt32Access type: Read-only Qualifiers: [read]Number of deployment types that depend on this application.
NumberOfDependentTS

Data type: UInt32Access type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
NumberOfDeployments

Data type: UInt32Access type: Read-only Qualifiers: [read]Number of deployments.
NumberOfDeploymentTypes

Data type: UInt32Access type: Read-only Qualifiers: [read]Number of deployment types.
NumberOfDevicesWithApp

Data type: UInt32Access type: Read-only Qualifiers: [read]Number of devices with this application installed.
NumberOfDevicesWithFailure

Data type: UInt32Access type: Read-only Qualifiers: [read]Number of devices that failed to install this application.
NumberOfUsersWithApp

Data type: UInt32Access type: Read-only Qualifiers: [read]Number of users with this application installed.
NumberOfUsersWithFailure

Data type: UInt32Access type: Read-only Qualifiers: [read]Number of users that failed to install this application.
NumberOfUsersWithRequest

Data type: UInt32Access type: Read-only Qualifiers: [read]Number of users that requested this application.
NumberOfVirtualEnvironments

Data type: UInt32Access type: Read-only Qualifiers: [read]Number of virtual environments which refer to the deployment types of this application.This information applies only to System Center 2012 Configuration Manager SP1 and System Center 2012 R2 Configuration Manager.
PackageID

Data type: StringAccess type: Read/Write Qualifiers: [lazy]The package identifier of the content. A unique key, that the user can set, otherwise the system will generate a default identifier. A reference to the same package identifier is in the SMS_CIContentPackage class.This information applies only to System Center 2012 Configuration Manager SP1 and System Center 2012 R2 Configuration Manager.
PermittedUses

Data type: UInt32Access type: Read/Write Qualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
PlatformCategoryInstance_UniqueIDs

Data type: String Array Access type: Read/Write Qualifiers: noneSee SMS_ConfigurationItemLatestBaseClass Server WMI Class.
PlatformType

Data type: UInt32Access type: Read-only Qualifiers: [bitmap, bitvalues, read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
SDMPackageLocalizedData

Data type: SMS_SDMPackageLocalizedData Array Access type: Read/Write Qualifiers: [lazy]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
SDMPackageVersion

Data type: UInt32Access type: Read/Write Qualifiers: [not_null]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
SDMPackageXML

Data type: StringAccess type: Read/Write Qualifiers: [lazy]Digest XML that defines the application.
SecuredScopeNames

Data type: String Array Access type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
SedoObjectVersion

Data type: StringAccess type: Read-only Qualifiers: [read]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
SoftwareVersion

Data type: StringAccess type: Read-only Qualifiers: [read]Software version description
SourceCIVersion

Data type: UInt32Access type: Read-only Qualifiers: [read]Source application version if the application is imported.
SourceModelName

Data type: StringAccess type: Read-only Qualifiers: [read]Source application model name if the application is imported.
SourceSite

Data type: StringAccess type: Read/Write Qualifiers: [sizelimit]See SMS_ConfigurationItemLatestBaseClass Server WMI Class.
SummarizationTime

Data type: DateTimeAccess type: Read-only Qualifiers: [read]Last time the summarization task was run for this application.

Remarks

Requirements

Runtime Requirements

Development Requirements

See Also