Outbound connectors allow you to take performance, event, and alert data from Operations Manager and insert it into an external management system. The following process describes how to implement an outbound connector:
- Create a new instance of the Microsoft.EnterpriseManagement.ConnectorFramework.MonitoringConnector
class that will represent the connector.
- Create an alert subscription. This is a different subscription
than one that is created for alert notifications. Operations
Manager uses the alert subscription as the criteria that determines
which alerts should be marked for the connector.
- If the connector needs to retrieve alerts from multiple tiers,
the connector must register with all the tiers from which it needs
to retrieve alerts.
- Regularly call GetMonitoringAlerts to retrieve alerts.
There is no notification mechanism for the connector to be notified
when new alerts are available for the connector, so the method must
be called multiple times to retrieve all the alerts.
- The connector must acknowledge all the alerts it receives,
otherwise, the connector receives duplicate alerts.
The following example shows how to create an outbound connector that allows you to take alert data from Operations Manager and insert it into an external management system.
| Visual Basic | Copy Code |
|---|---|
Imports System
Imports System.Collections.Generic
Imports System.Text
Imports Microsoft.EnterpriseManagement
Imports Microsoft.EnterpriseManagement.ConnectorFramework
Imports Microsoft.EnterpriseManagement.Common
Imports Microsoft.EnterpriseManagement.Monitoring
Imports System.Collections.ObjectModel
Imports System.Threading
Namespace SDKSamples
Class Program
Public Overloads Shared Function Main(ByVal args() As String) As Integer
Dim mg As ManagementGroup = New ManagementGroup("localhost")
Dim cfAdmin As ConnectorFrameworkAdministration = mg.GetConnectorFrameworkAdministration()
Dim connectorGuid As Guid = New Guid("{6A1F8C0E-B8F1-4147-8C9B-5A2F98F10003}")
Dim connector As MonitoringConnector
Try
If (args.Length = 1) Then
If (args(0) = "InstallConnector") Then
Dim info As ConnectorInfo = New ConnectorInfo()
info.Description = "Sample connector"
info.DisplayName = "Sample connector"
info.Name = "Sample connector"
connector = cfAdmin.Setup(info, connectorGuid)
connector.Initialize()
End If
If (args(0) = "UninstallConnector") Then
connector = cfAdmin.GetMonitoringConnector(connectorGuid)
Dim subscriptions As ReadOnlyCollection(Of MonitoringConnectorSubscription)
subscriptions = cfAdmin.GetConnectorSubscriptions()
For Each subscription As MonitoringConnectorSubscription In subscriptions
If (subscription.MonitoringConnectorId = connectorGuid) Then
cfAdmin.DeleteConnectorSubscription(subscription)
End If
Next
connector.Uninitialize()
cfAdmin.Cleanup(connector)
End If
Return 0
End If
connector = cfAdmin.GetMonitoringConnector(connectorGuid)
While (True)
Dim alerts As ReadOnlyCollection(Of ConnectorMonitoringAlert)
alerts = connector.GetMonitoringAlerts()
If (alerts.Count > 0) Then
connector.AcknowledgeMonitoringAlerts(alerts)
End If
For Each alert As ConnectorMonitoringAlert In alerts
' Send the alert to the other management system with the appropriate API
' from the other management system.
' Add a comment to the alert.
alert.Update("Alert has been forwarded to the management system")
Next
' Wait for a minute before checking for new alerts again.
Thread.Sleep(60 * 1000)
End While
Catch e As MonitoringException
Console.WriteLine(e.Message)
End Try
End Function
End Class
End Namespace
|
|
| C# | Copy Code |
|---|---|
using System;
using System.Collections.Generic;
using System.Text;
using Microsoft.EnterpriseManagement;
using Microsoft.EnterpriseManagement.ConnectorFramework;
using Microsoft.EnterpriseManagement.Common;
using Microsoft.EnterpriseManagement.Monitoring;
using System.Collections.ObjectModel;
using System.Threading;
namespace OutboundConnector
{
class Program
{
static void Main(string[] args)
{
ManagementGroup mg = new ManagementGroup("localhost");
ConnectorFrameworkAdministration cfAdmin = mg.GetConnectorFrameworkAdministration();
Guid connectorGuid = new Guid("{6A1F8C0E-B8F1-4147-8C9B-5A2F98F10003}");
MonitoringConnector connector;
try
{
if (args.Length == 1)
{
if (args[0] == "InstallConnector")
{
ConnectorInfo info = new ConnectorInfo();
info.Description = "Sample connector";
info.DisplayName = "Sample connector";
info.Name = "Sample connector";
connector = cfAdmin.Setup(info, connectorGuid);
connector.Initialize();
}
else if (args[0] == "UninstallConnector")
{
connector = cfAdmin.GetMonitoringConnector(connectorGuid);
ReadOnlyCollection<MonitoringConnectorSubscription> subscriptions;
subscriptions = cfAdmin.GetConnectorSubscriptions();
foreach (MonitoringConnectorSubscription subscription in subscriptions)
{
if (subscription.MonitoringConnectorId == connectorGuid)
{
cfAdmin.DeleteConnectorSubscription(subscription);
}
}
connector.Uninitialize();
cfAdmin.Cleanup(connector);
}
return;
}
connector = cfAdmin.GetMonitoringConnector(connectorGuid);
while (true)
{
ReadOnlyCollection<ConnectorMonitoringAlert> alerts;
alerts = connector.GetMonitoringAlerts();
if (alerts.Count > 0)
{
connector.AcknowledgeMonitoringAlerts(alerts);
}
foreach (ConnectorMonitoringAlert alert in alerts)
{
//Send the alert to the other management system with the appropriate API
//from the other management system.
//Add a comment to the alert.
alert.Update("Alert has been forwarded to the management system");
}
//Wait for a minute before checking for new alerts again.
Thread.Sleep(60 * 1000);
}
}
catch (MonitoringException error)
{
Console.WriteLine(error.Message);
}
}
}
}
|
|
Send comments about this topic to Microsoft.