Previous Next
Opalis Integration Pack for HP OpenView Operations (Windows) > Objects > Acknowledge Message

Acknowledge Message
The Acknowledge Message object acknowledges messages in OpenView Operations signifying that a message has been addressed. Once acknowledged, a message will not be visible in the OpenView Operations console. You can also use the Acknowledge Message operator to unacknowledged a message.
How it is used
The Acknowledge Message object can be used to close an OpenView Operations message after a Policy has performed diagnostics and determined that the message is a false positive.
Configuration
To configure the Acknowledge Message object you need to know the OpenView Operations server you are connecting to and the message that you are acknowledging.
Details tab
 
OVO-W Server
Type the name of the Management Server connection that you want to use, or click the ellipsis () button and browse for it. You must configure the available connections through the HP OpenView Operations (Windows) Options dialog.
ID Number
Type the ID of the message that you are updating. Opalis Software, Inc. recommends that you use Published Data from the Create Message, Acknowledge Message, Own/Disown Message, Get Message, Add Annotation to Message, Update Message, or Monitor Message objects to specify the ID of the message.
Acknowledge
Select to acknowledge the message and remove it from the OpenView Operations console.
Unacknowledge
Select to unacknowledged the message return it to the OpenView Operations console.
Available Published Data
 
Name
Description
Message Id
The Id of the message that was updated.
Acknowledge
The acknowledgement action that was performed on the message. The value of this Published Data will be ‘Acknowledge’ or ‘Unacknowledge’.
OVO-W server
The name of the OpenView Operations server where the message is stored.
Common Published Data