Alert Processing rules

Alert Processing rules are defined to generate an alert from NT Events that are generated from the HP BladeSystem Enclosure Monitor Service. The HP BladeSystem Enclosure Monitor Service logs all events into the HP BladeSystem event log. The Appendix describes all the defined events that are generated by the HP BladeSystem Enclosure Monitor Service.

The following event processing rules are identified in the management pack to generate Alerts for SNMP Trap based events:

Event ID

Event type

Message title

11003

Warning

Test Alert.

22005

Error

Rack Enclosure Overheated

22006

Warning

Rack Enclosure Overheating.

22008

Error

Rack Enclosure Fan Failed.

22009

Warning

Rack Enclosure Fan Degraded.

22013

Error

Rack Power Supply Failed.

22014

Warning

Rack Power Supply Degraded.

22018

Warning

Rack Power Subsystem Not Redundant.

22019

Warning

Rack Power Subsystem Input Voltage Problem.

22020

Warning

Rack Power Subsystem Overload.

22037

Warning

Onboard Administrator Degraded.

22041

Warning

Onboard Administrator Role Primary.

22042

Warning

Server Blade E-keying Failed.

22046

Error

Interconnect Failed.

22047

Warning

Interconnect Degraded.

22055

Error

Server blade group capper error.

Additionally, the following alert processing rules have been defined for the Monitor Service events. The following events are monitored and generate alerts with Knowledge Base:

Event ID

Event type

Message title

Alert name

3

Error

SNMP Trap Service is not available

SNMP trap service failed.

14

Error

Connection to Enclosure Failed.

Connection to enclosure failed.

19

Error

Data Collection Failed.

Data collection failed.

23

Warning

Health Check Restarted a monitoring.

Health check degraded.

24

Error

Health Check Failed to Stop a monitoring.

Health check failed.

25

Error

Monitor Service Failed to load the configuration data.

Health check failed.

26

Error

Monitor Service Failed to respond.

Health check failed.